Updated on 2025/12/03

All information, except for affiliations, is reprinted from the information registered on researchmap.

写真a

 
Tomoaki Akiyama
 
Organization
YCU Medical Center Endocrinology Diabetes and Metabolism Assistant Professor
Title
Assistant Professor
External link

Research Areas

  • Others / Others

Papers

  • Efficacy of MiniMed™ 780G® on glucose management, sleep quality, and psychological aspects in persons with type 1 diabetes treated with MiniMed™ 770G®: A 3-month prospective single-center observational study.

    Tomoaki Akiyama, Kazuki Orime, Ryoichi Akamatsu, Taichi Suezono, Mako Akiyama, Arisa Matsuura, Ayano Kaneko, Tadashi Yamakawa, Satoru Shinoda, Yasuo Terauchi

    Journal of diabetes investigation   2025.11

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    AIMS/INTRODUCTION: The MiniMed™ 780G® is effective for improving glycemic control; however, few studies have specifically examined the impact of upgrading from MiniMed™ 770G® to MiniMed™ 780G® in adults. We determined the effects of upgrading from MiniMed™ 770G® to MiniMed™ 780G® (780G) on glucose management, psychological distress, daily life quality, and sleep in type 1 diabetes mellitus (T1DM). MATERIALS AND METHODS: In this single-center prospective study, we observed 21 adults who transitioned from the MiniMed™ 770G® to the 780G for 3 months. Glycemic outcomes, insulin delivery parameters, frequency of alarms, and sensor calibrations were assessed. Patient-reported outcomes were evaluated using the Problem Areas in Diabetes (PAID), the Diabetes Treatment Satisfaction Questionnaire status version, the Diabetes Therapy-Related Quality of Life, and the Pittsburgh Sleep Quality Index. RESULTS: Glycated hemoglobin (HbA1c) decreased (7.5 ± 1.3%-7.0 ± 0.8%, mean difference: -0.5%, 95% Confidence Interval (CI): -0.9 to -0.1; P = 0.018). Time in tight range (TITR) showed trends toward improvement (44.9 ± 15.5%-48.9 ± 15.5%, mean difference: 4.0%, 95% CI: -0.7 to 8.6; P = 0.090). Alarm frequency declined (11.9 ± 8.7-7.1 ± 5.5 times/day, mean difference: -4.8, 95% CI: -7.0 to -2.6; P = 0.0002), and calibration frequency decreased (3.6 ± 2.2-0.8 ± 0.6 times/day, mean difference: -2.8, 95% CI: -3.7 to -1.9; P < 0.0001). The PAID score improved, decreasing from 38.7 ± 19.9 to 31.7 ± 19.3 (mean difference: -7.0, 95% CI: -14.7 to 0.7; P = 0.074). CONCLUSIONS: Favorable changes in HbA1c, TITR, and PAID scores suggest potential glycemic and psychological benefits.

    DOI: 10.1111/jdi.70198

    PubMed

    researchmap

  • Type 1 Diabetes Mellitus with Diabetic Ketoacidosis Presenting with Transient Severe Fatty Liver and Subsequent Liver Dysfunction.

    Takayuki Suzuki, Kazuki Orime, Ryoichi Akamatsu, Tomoaki Akiyama, Tadashi Yamakawa, Yasuo Terauchi

    Internal medicine (Tokyo, Japan)   63 ( 24 )   3339 - 3344   2024.12

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    Patients often present with severe fatty liver (FL) due to insulin deficiency at the onset of diabetic ketoacidosis (DKA). On the other hand, glycogenic hepatopathy (GH) is a possible cause of liver dysfunction in patients with DKA. We herein report a case of type 1 diabetes mellitus with severe FL at the onset of DKA, who demonstrated subsequent marked liver dysfunction after achieving an improvement of FL. As liver dysfunction persisted even after the FL improved, GH was suspected to be the cause of liver dysfunction. FL and GH have different prognoses and should therefore be differentiated using imaging studies and biopsies.

    DOI: 10.2169/internalmedicine.3488-24

    PubMed

    researchmap

  • Effects of hybrid closed-loop system on glycemic control and psychological aspects in persons with type 1 diabetes treated with sensor-augmented pump: A prospective single-center observational study.

    Tomoaki Akiyama, Tadashi Yamakawa, Kazuki Orime, Masahiro Ichikawa, Marina Harada, Takumi Netsu, Ryoichi Akamatsu, Keita Nakamura, Satoru Shinoda, Yasuo Terauchi

    Journal of diabetes investigation   2023.11

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    AIMS/INTRODUCTION: This study evaluated the effects of the Medtronic MiniMed 770G hybrid closed-loop system on glycemic control and psychological aspects in persons with type 1 diabetes mellitus. MATERIALS AND METHODS: This 3-month prospective observational study included 22 participants with type 1 diabetes mellitus who used the Medtronic MiniMed 640G predictive low-glucose suspend system and were switched to the 770G system. Time in the range of 70-180 mg/dL and glycated hemoglobin levels were evaluated; satisfaction, emotional distress and quality of life were assessed using self-reported questionnaires, including the Diabetes Treatment Satisfaction Questionnaire Status, Problem Area in Diabetes and Diabetes Therapy-Related Quality of Life. RESULTS: Time in the range of 70-180 mg/dL increased (63.5 ± 13.4 to 73.0 ± 10.9% [mean ± standard deviation], P = 0.0010), and time above the range of 181-250 mg/dL decreased (26.9 ± 8.9 to 19.6 ± 7.1%, P < 0.0005). Glycated hemoglobin levels decreased (7.7 ± 1.0 to 7.2 ± 0.8%, P = 0.0021). The percentage of participants with time below the range of 54-69 mg/dL <4% of readings increased from 91% to 100% (P < 0.0005). No significant changes were detected in the satisfaction, emotional distress and quality of life levels, but increased sensor calibration might be related to worsened emotional distress and quality of life. CONCLUSIONS: The hybrid closed-loop system decreased hyperglycemia and minimized hypoglycemia, but did not improve psychological aspects compared with the predictive low-glucose suspend system, probably because sensor calibration was increased.

    DOI: 10.1111/jdi.14103

    PubMed

    researchmap

  • Sleep duration and food intake in people with type 2 diabetes mellitus and factors affecting confectionery intake.

    Tomoaki Akiyama, Tadashi Yamakawa, Kazuki Orime, Jun Suzuki, Rika Sakamoto, Minori Matsuura-Shinoda, Erina Shigematsu, Kenichiro Takahashi, Mizuki Kaneshiro, Taro Asakura, Shunichi Tanaka, Takehiro Kawata, Yoshihiko Yamada, Tetsuo Isozaki, Atsushi Takahashi, Uru Nezu Osada, Kazuaki Kadonosono, Yasuo Terauchi

    Journal of diabetes investigation   14 ( 5 )   716 - 724   2023.5

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    AIMS/INTRODUCTION: We carried out a cross-sectional study of people with type 2 diabetes mellitus to elucidate the association between sleep duration and food intake. MATERIALS AND METHODS: Overall, 2,887 participants with type 2 diabetes mellitus (mean age 63.0 years; 61.1% men; mean glycated hemoglobin level 7.5%) were included in this study. The participants' self-reported dietary habits and sleep duration were evaluated using a brief self-administered dietary history questionnaire and Pittsburgh Sleep Quality Index, respectively. The participants were categorized into the following four groups based on sleep duration: <6, 6-6.9, 7-7.9 (reference) and ≥8 h. RESULTS: No significant differences were observed between the groups regarding energy intake (kcal/day), absolute intake (g/day) or relative intake (% energy) of carbohydrates, total fat, proteins and fibers. However, confectionery intake was higher in the <6 h group and lower in the ≥8 h group than in the reference group after adjustment for confounding factors. In multivariate analysis, sleep durations <6 h and ≥8 h significantly correlated with increased (95% confidence interval 0.55 to 3.6; P = 0.0078) and decreased (95% confidence interval -4.0 to -0.32; P = 0.021) confectionery intake, respectively. Confectionery intake was positively correlated with female sex, glycated hemoglobin level and dyslipidemia, whereas it was negatively correlated with alcohol consumption and current smoking status. CONCLUSIONS: Short sleep duration is associated with high confectionery intake in people with type 2 diabetes mellitus; this might disturb their glycemic control. Therefore, short sleepers with type 2 diabetes mellitus could improve their glycemic control by avoiding confectionery intake and maintaining adequate sleep duration.

    DOI: 10.1111/jdi.13987

    PubMed

    researchmap

  • The METRO study: a retrospective analysis of the efficacy of metformin for type 2 diabetes in Japan.

    Marina Harada, Yoshinobu Kondo, Mai Sugiyama, Akeo Ohira, Masahiro Ichikawa, Tomoaki Akiyama, Kazuki Orime, Takanori Takai, Tadashi Yamakawa, Yasuo Terauchi

    Endocrine journal   70 ( 1 )   121 - 128   2023.1

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    Metformin monotherapy as first-line treatment for patients with type 2 diabetes (T2D) has been shown to effectively improve blood glucose levels and motivation to undergo treatment and prevent complications. However, no studies have reported its effect when combined with other drugs or compared the effect based on administration time. This study aimed to investigate the effect of metformin administration in Japanese patients with T2D, examine how the introduction line impacts the effect of metformin, and examine the characteristics of patients demonstrating improved blood glucose levels. Data on characteristics of patients who were newly prescribed metformin with no shifting of hypoglycemic agents in the subsequent 24-week observation period, and their age [mean, 56.8 years], body mass index [mean, 27.5 kg/m2], glycated hemoglobin [HbA1c] [mean, 8.1%], and duration of diabetes [mean, 3.0 years] were obtained from the medical records of 201 patients. The changes in HbA1c by introduction line after 24 weeks were -1.59%, -0.91%, -0.89%, and -0.65% in the first, second, third, and fourth induction lines, respectively; earlier introduction more significantly improved blood glucose. The factors significantly associated with HbA1c changes were early introduction, high baseline HbA1c, high estimated glomerular filtration rate, decreased insulin secretion, short estimated duration of diabetes, and increased metformin dose. Furthermore, factors contributing to the largest HbA1c improvement by metformin were high baseline HbA1c and early administration. Metformin is expected to lower blood glucose levels in Japanese patients with T2D, even in those with decreased insulin secretion, due to its early introduction as a first-line drug.

    DOI: 10.1507/endocrj.EJ22-0330

    PubMed

    researchmap

  • Comparing the course and delivery outcomes of Japanese twin pregnancies with and without gestational diabetes mellitus: a single-center retrospective analysis.

    Mai Sugiyama, Tadashi Yamakawa, Marina Harada, Akeo Ohira, Masahiro Ichikawa, Tomoaki Akiyama, Kazuki Orime, Sayuri Nakanishi, Shigeru Aoki, Yasuo Terauchi

    Endocrine journal   69 ( 10 )   1183 - 1191   2022.10

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    Singleton pregnant women with gestational diabetes mellitus (GDM) are at an increased risk of adverse maternal and neonatal outcomes. Multiple pregnancies are associated with increased risks of perinatal complications; however, the impact of GDM on maternal and neonatal outcomes in multiple pregnancies is unknown, and there are currently few reports on GDM status in twin pregnancies. This study aimed to compare the background and perinatal outcomes between Japanese twin pregnancies with and without GDM at a perinatal center in Japan. Additionally, the clinical course of GDM was investigated. In this retrospective cohort study, women with twin pregnancies underwent GDM screening at Yokohama City University Medical Center from January 2011 to December 2016. Overall, 307 twin pregnancies were divided into GDM (47 cases, 15.3%) and non-GDM (260 cases, 84.7%) groups. GDM-associated pregnancy complications, GDM status, and pregnancy outcomes were ascertained. Women with GDM were older and had a higher pre-pregnancy body mass index than those without GDM. Glycemic control was good in all patients, and there was no difference in delivery outcomes between the two groups. Gestational weight gain was lower in pregnant women with GDM (+8.0 kg) than in those without GDM (+11.8 kg), suggesting the impact of strict nutritional guidance on twin pregnancies with GDM. In conclusion, twin pregnancies with GDM did not have different delivery outcomes compared to those without GDM. To manage twin pregnancies with GDM, this study suggests that it is important to monitor patients' weight and blood glucose levels.

    DOI: 10.1507/endocrj.EJ21-0537

    PubMed

    researchmap

  • Association of continuous positive airway pressure therapy on cardiac hypertrophy in patients with sleep apnea comorbid with type 2 diabetes mellitus.

    Akeo Ohira, Tadashi Yamakawa, Noriaki Iwahashi, Shunichi Tanaka, Mai Sugiyama, Marina Harada, Masahiro Ichikawa, Tomoaki Akiyama, Kazuki Orime, Yasuo Terauchi

    Endocrine journal   70 ( 1 )   47 - 58   2022.9

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    Previous reports indicated the therapeutic effect of chronic continuous positive airway pressure (CPAP) therapy on cardiac hypertrophy due to sleep apnea syndrome. However, little is known for cases involving diabetic complications. This retrospective observational study examined the effects of CPAP therapy on left ventricular hypertrophy (LVH) in patients with obstructive sleep apnea syndrome (OSAS) and type 2 diabetes mellitus (T2DM). For all cases, the observation period was 3 years from the time when the patient was introduced to CPAP therapy. Overall, 123 patients were divided into a good CPAP group (CPAP ≥4 h/day, n = 63) and non-adherence group (CPAP <4 h/day, n = 60). The mean CPAP usage times were 5.58 ± 1.23 and 1.03 ± 1.17 h/day in the good CPAP and non-adherence groups, respectively. Regression tendencies of the thickness of the left ventricular posterior (-0.30 ± 1.19 mm) and interventricular septal walls (-0.48 ± 1.22 mm) were observed in the good CPAP group. Hypertrophic tendencies of the left ventricular posterior wall (+0.59 ± 1.44 mm) and interventricular septal wall thickness (+0.59 ± 1.43) were observed in the non-adherence group. Left ventricular posterior wall thickness (odds ratio, (coefficient: -0.254, p = 0.0376) and interventricular septal wall thickness (coefficient: -0.426, p = 0.0006) were more likely to be greater in the non-adherence group than in the good CPAP group. Patients in the non-adherence group with an apnea hypopnea index ≥30 had increased left ventricular posterior wall thickness (coefficient: -0.263, p = 0.0673) and interventricular septal wall thickness (coefficient: -0.450, p = 0.0011). In conclusion, appropriate CPAP therapy is an effective treatment for LVH in patients with T2DM and OSAS, especially for severe cases.

    DOI: 10.1507/endocrj.EJ22-0308

    PubMed

    researchmap

  • Diagnostic accuracy of home sleep apnea testing using peripheral arterial tonometry for sleep apnea: A systematic review and meta-analysis. International journal

    Masahiro Ichikawa, Tomoaki Akiyama, Yasushi Tsujimoto, Keisuke Anan, Tadashi Yamakawa, Yasuo Terauchi

    Journal of sleep research   31 ( 6 )   e13682   2022.7

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    This study aimed to evaluate the diagnostic accuracy of home sleep apnea testing using peripheral arterial tonometry for sleep apnea as an alternative to polysomnography. We conducted a systematic review and meta-analysis of observational studies, randomized controlled trials, and diagnostic case-control studies examining the diagnostic accuracy of peripheral arterial tonometry by searching the CENTRAL, MEDLINE, EMBASE, ICTRP and ClinicalTrials.gov databases on 5 October 2021. We assessed the risk of bias of the included studies using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. A bivariate random-effects model was generated to derive the summary point estimates of sensitivity and specificity with 95% confidence intervals at different apnea-hypopnea index cutoffs. This meta-analysis included 13 studies (1227 participants, median prevalence of sleep apnea with apnea-hypopnea index ≥ 5 events per hr: 85%). The risk of bias in the included studies was low to moderate. The pooled sensitivity and specificity estimates were 96% (95% confidence interval: 93%-97%) and 44% (95% confidence interval: 32%-56%) at apnea-hypopnea index ≥ 5 events per hr, 88% (85%-91%) and 74% (63%-83%) at apnea-hypopnea index ≧ 15 events per hr, and 80% (66%-89%) and 90% (83%-95%) at apnea-hypopnea index ≧ 30 events per hr, respectively. Peripheral arterial tonometry resulted in a significant number of false negatives and false positives at any apnea-hypopnea index cutoff when applied to the median prevalence setting of the included studies. The inadequate sensitivity and specificity of peripheral arterial tonometry render it an unsuitable alternative to polysomnography for detecting sleep apnea for apnea-hypopnea index ≧ 5, 15 and 30 events per hr.

    DOI: 10.1111/jsr.13682

    PubMed

    researchmap

  • Efficacy of education on injection technique for patients diagnosed with diabetes with lipohypertrophy: systematic review and meta-analysis. International journal

    Masahiro Ichikawa, Tomoaki Akiyama, Yasushi Tsujimoto, Keisuke Anan, Tadashi Yamakawa, Yasuo Terauchi

    BMJ open   12 ( 3 )   e055529   2022.3

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    OBJECTIVES: This study aimed to investigate the efficacy of providing education on injection technique to patients with diabetes with lipohypertrophy (LH). DESIGN: We conducted a systematic review and meta-analysis. METHODS: We included patients with diabetes who use insulin and have LH, and excluded patients without LH. We performed a literature search on CENTRAL, MEDLINE, EMBASE, ICTRP and ClinicalTrials.gov in November 2021 for randomised controlled trials (RCTs). We used the revised Cochrane Risk of Bias 2 tool to evaluate the risk of bias in each outcome in each study. We then pooled the data using a random-effects model and evaluated the certainty of evidence using the Grading of Recommendations, Assessment, Development and Evaluation approach. OUTCOME MEASURES: The primary endpoints were change in total daily dose (TDD) of insulin, change in HbA1c levels and prevalence of hypoglycaemia. RESULTS: We screened 580 records and included three RCTs (637 participants) in the meta-analysis. Education on injection technique may slightly increase the change of TDD of insulin (three studies, 637 participants: mean difference (MD) -6.26; 95% CI -9.42 to -3.10; p<0.001; I2=38%; low certainty of evidence) and may have little to no effect on change in HbA1c but the evidence is very uncertain compared with that in the control group (three studies, 637 participants: MD -0.59; 95% CI -1.71 to 0.54; p=0.31; I2=98%; very low certainty of evidence). Providing education about injection technique may have little to no effect on the prevalence of hypoglycaemia (three studies, 637 participants: risk ratio 0.44; 95% CI 0.06 to 3.13; p=0.41; I2=90%; very low certainty of evidence). CONCLUSIONS: The present meta-analysis suggests that injection technique education may result in a slight reduction in the TDD of insulin. However, the effect of education on HbA1c, hypoglycaemia and cured LH is uncertain. PROTOCOL REGISTRATION: DOI: dx.doi.org/10.17504/protocols.io.btiinkce.

    DOI: 10.1136/bmjopen-2021-055529

    PubMed

    researchmap

  • Predicting the ability of elderly diabetes patients to acquire the insulin self-injection technique based on the number of animal names recalled Reviewed

    Taichi Minami, Masayo Yamada, Ryutaro Furuta, Kentaro Kamata, Sho Katsuragawa, Sakiko Terui, Tomoaki Akiyama, Taishi Yoshii, Tetsuji Tsunoda, Yasuo Terauchi

    Journal of Diabetes Investigation   9 ( 3 )   623 - 628   2018.5

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:Blackwell Publishing  

    DOI: 10.1111/jdi.12732

    Scopus

    researchmap

▼display all